Step 1: Enable PCS
node1::> node run –node node1 node1::> options flexscale.enable on node1::>options flexscale.enable flexscale.enable pcs you should see this node1::>options flexscale.pcs_size 330GB based on 3 x 200GB SSD RAID4
Step 2: Allow the representative workload to run and Run your workload
Step 3: Collect data throughout the process
node1::>stats show -p flexscale-accessNetApp recommends issuing this command through an SSH connection and logging the output throughout the observation period because you want to capture and observe the peak performance of the system and the cache. This output can also be easily imported into spreadsheet software, graphed, and so on. This process initially provides information on the “cold” state of the emulated cache. That is, no data is in the cache at the start of the test, and the cache is filled as the workload runs. The best time to observe the emulated cache is once it is filled, or “warmed”, as this will be the point when it enters a steady state. Filling the emulated cache can take a considerable amount of time and depends greatly on the workload. References: